Last Updated on 28 June 2021 by Roberto De Pedrini
Let’s start with a brief introduction of “cloning” and “multipath” concepts.
Cloning (that is creating an exact copy of an existing IBM i system or partition) has been a concept for the IBM i platform since the introduction of boot from SAN (Storage Area Network) with i5/OS V5R3M5 (when the load source has been moved inside a SAN-attached storage subsystem without the needed to use remote load source mirroring to mirror your internal load source to the SAN-attached load source). The copy can be attached to another servers, a separate LPAR, or, if the production system is powered off, the existing partition or system. After the copy is created, you can use it for offline backup, system testing, or migration.
Boot from SAN enables you to take advantage of some of the advanced features that are available with IBM system storage. One of these functions is FlashCopy which allows you to perform a point-in-time instantaneous copy of the data held on a LUN or group of LUNs. Therefore, when you have a system that only has SAN LUNs with no internal drives, you can create a clone of your system.
IBM i supports multipath attachment through Fibre Channel as part of the base IBM i operating system support to provide greater resilience to storage area network (SAN) failures, which can be critical to IBM i due to the single-level storage architecture (multipath is the ability to present logical volumes on a storage device to the host server via multiple connections). Additionally, having multiple paths to a logical volume can improve the I/O performance of the partition.
Note: With IBM i operating system 6.1 or later, multipath attachment is supported on an external disk unit that acts as a load source for the IBM i host.
New paths are automatically detected, configured by the system, and immediately used. If a disk is initially set up as a single path and a second path is added, the resource name of the disk unit is modified from DDxxx
to DMPxxx
. This modification reflects that it now has more than one path to the disk unit. No user changes are required on the IBM i host to use the new path. Multipath connections can be directly connected or connected through a fabric.
Now, we combine the two concepts.
When you IPL a clone, a message CPI096E - Disk unit connection is missing
for each LUN connected by the missing path appears in the history log of the newly created IBM i LPAR (and it is re-posted every hour).
A check in DST/SST shows the expected disk paths as active
(or passive
, see note below for additional information) and extra disk paths with a status of missing
, as result of the reconfiguration of the disk subsystem (missing paths are the connections to the disk units of the cloned system):
Serial Resource Path
ASP Unit Number Type Model Name Status
1 1 YF4FE4000034 2145 050 DMP005 Active
YF4FE4000034 2145 050 DMP001 Passive
YF4FE4000034 2145 050 DMP002 Active
YF4FE4000034 2145 050 DMP015 Passive
YF501C00000F 2145 050 DMP011 Missing
YF501C00000F 2145 050 DMP012 Missing
YF501C00000F 2145 050 DMP013 Missing
YF501C00000F 2145 050 DMP014 Missing
1 2 YF4FE4000035 2145 050 DMP006 Passive
YF4FE4000035 2145 050 DMP003 Active
YF4FE4000035 2145 050 DMP016 Active
YF4FE4000035 2145 050 DMP004 Passive
YF501C000010 2145 050 DMP007 Missing
YF501C000010 2145 050 DMP010 Missing
YF501C000010 2145 050 DMP009 Missing
YF501C000010 2145 050 DMP008 Missing
Note: Every LUN in Storwize V7000 uses one V7000 node as a preferred node. The I/O traffic to or from the particular LUN normally goes through the preferred node. If that node fails, the I/O is transferred to the remaining node. With IBM i multipath, all the paths to a LUN through the preferred node are active
and the path through the non-preferred node is passive
. Multipath employs the load balancing among the paths to a LUN that go through the node, which is preferred for that LUN.
To avoid the warnings and to clean up the disk paths you can run the Multipath Resetter Advanced Analysis macro in DST/SST, or QYASSDMO API. Using QYASSDMO API allows you to avoid access to the DST/SST and to automate the task.
Below is a very simple example of using QYASSDMO API to perform a multipath reset.
Target operating system: IBM i V7R2 (SF99720 level 20296 and SF99717 level 9), IBM i V7R3 (SF99730 level 19311 – SF99727 level 7, and SF99730 level 21098 – SF99727 level 10).
Note: On my clone systems using IBM i V7R3 with SF99730 level 19311, the missing paths are not shown in SST but only reported with CPI096E
messages in the history log. They became visible again in SST after installing SF99730 level 21098, current level at the time of writing this post.
Prerequisite: An IBM i system with only SAN LUNs (no internal drives).
CMD source:
CMD PROMPT('Multipath Resetter')
PARM KWD(ASP) TYPE(*UINT4) RSTD(*NO) DFT(1) +
RANGE(1 255) CHOICE('1, 2, ...') +
PROMPT('Enter ASP No:')
CLLE source:
PGM PARM(&P_ASP)
/* Parameters */
DCL VAR(&P_ASP) TYPE(*UINT) LEN(4)
/* QYASSDMS, QYASSDMO, QYASEDMS */
DCL VAR(&HANDLE) TYPE(*CHAR) LEN(8)
/* QYASSDMO */
DCL VAR(&OPKEY) TYPE(*CHAR) LEN(4)
DCL VAR(&DMOP0700) TYPE(*CHAR) LEN(20)
DCL VAR(&ASP_OFFSET) TYPE(*INT) STG(*DEFINED) +
LEN(4) DEFVAR(&DMOP0700 1)
DCL VAR(&ASP_QTY) TYPE(*INT) STG(*DEFINED) +
LEN(4) DEFVAR(&DMOP0700 5)
DCL VAR(&ASP_OPER) TYPE(*INT) STG(*DEFINED) +
LEN(4) DEFVAR(&DMOP0700 9)
DCL VAR(&ASP_RES) TYPE(*INT) STG(*DEFINED) +
LEN(4) DEFVAR(&DMOP0700 13)
DCL VAR(&ASP_ARRAY) TYPE(*CHAR) STG(*DEFINED) +
LEN(4) DEFVAR(&DMOP0700 17)
DCL VAR(&DMOP0700L) TYPE(*INT) LEN(4) VALUE(20)
DCL VAR(&FORMAT) TYPE(*CHAR) LEN(8)
DCL VAR(&APINAME) TYPE(*CHAR) LEN(10)
DCL VAR(&MSGDTA) TYPE(*CHAR) LEN(512)
/* API Error */
DCL VAR(&APIERROR) TYPE(*CHAR) LEN(528)
DCL VAR(&AEBYTPRO) TYPE(*INT) STG(*DEFINED) +
LEN(4) DEFVAR(&APIERROR 1)
DCL VAR(&AEBYTAVL) TYPE(*INT) STG(*DEFINED) +
LEN(4) DEFVAR(&APIERROR 5)
DCL VAR(&AEEXCPID) TYPE(*CHAR) STG(*DEFINED) +
LEN(7) DEFVAR(&APIERROR 9)
DCL VAR(&AEEXCPDTA) TYPE(*CHAR) STG(*DEFINED) +
LEN(512) DEFVAR(&APIERROR 17)
MONMSG MSGID(CPF0000 MCH0000) EXEC( +
GOTO CMDLBL(ERROR))
/* Start DASD Management Session - QYASSDMS API */
CALL PGM(QYASSDMS) PARM(&HANDLE &APIERROR)
IF COND(&AEBYTAVL *NE 0) THEN(DO)
CHGVAR VAR(&APINAME) VALUE('QYASSDMS')
GOTO CMDLBL(ERROR)
ENDDO
/* Start DASD Management Operation - QYASSDMO API */
CHGVAR VAR(%BIN(&OPKEY 1 4)) VALUE(16)
CHGVAR VAR(&ASP_OFFSET) VALUE(16)
CHGVAR VAR(&ASP_QTY) VALUE(1)
CHGVAR VAR(&ASP_OPER) VALUE(0)
CHGVAR VAR(&ASP_RES) VALUE(0)
CHGVAR VAR(%BIN(&ASP_ARRAY 1 4)) VALUE(&P_ASP)
CHGVAR VAR(&FORMAT) VALUE('DMOP0700')
CALL PGM(QYASSDMO) PARM(&HANDLE &OPKEY &DMOP0700 +
&DMOP0700L &FORMAT &APIERROR)
IF COND(&AEBYTAVL *NE 0) THEN(DO)
CHGVAR VAR(&APINAME) VALUE('QYASSDMO')
GOTO CMDLBL(ERROR)
ENDDO
/* End DASD Management Session - QYASEDMS API */
CALL PGM(QYASEDMS) PARM(&HANDLE &APIERROR)
IF COND(&AEBYTAVL *NE 0) THEN(DO)
CHGVAR VAR(&APINAME) VALUE('QYASEDMS')
GOTO CMDLBL(ERROR)
ENDDO
CHGVAR VAR(&MSGDTA) VALUE('Multipath reset for ASP' +
*BCAT %CHAR(&P_ASP) *BCAT 'completed')
SNDPGMMSG MSGID(CPF9898) MSGF(QSYS/QCPFMSG) +
MSGDTA(&MSGDTA) TOPGMQ(*PRV (*)) +
TOMSGQ(*TOPGMQ) MSGTYPE(*INFO)
RETURN:
RETURN
ERROR:
IF COND(&AEBYTAVL *NE 0) THEN( +
SNDPGMMSG MSGID(&AEEXCPID) MSGF(QSYS/QCPFMSG) +
MSGDTA(&AEEXCPDTA) TOPGMQ(*PRV (*)) +
TOMSGQ(*TOPGMQ) MSGTYPE(*DIAG))
CALL PGM(QYASEDMS) PARM(&HANDLE &APIERROR)
MONMSG MSGID(CPF0000)
CHGVAR VAR(&MSGDTA) VALUE('Command ended with error')
SNDPGMMSG MSGID(CPF9898) MSGF(QSYS/QCPFMSG) +
MSGDTA(&MSGDTA) TOPGMQ(*PRV (*)) +
TOMSGQ(*TOPGMQ) MSGTYPE(*ESCAPE)
ENDPGM:
ENDPGM
After executing the command MPATHRESET ASP('1')
, missing disk paths have disappeared from SST and CPI096E
messages are no longer sent in the history log:
Serial Resource Path
ASP Unit Number Type Model Name Status
1 1 YF4FE4000034 2145 050 DMP005 Active
YF4FE4000034 2145 050 DMP001 Passive
YF4FE4000034 2145 050 DMP002 Active
YF4FE4000034 2145 050 DMP015 Passive
1 2 YF4FE4000035 2145 050 DMP006 Passive
YF4FE4000035 2145 050 DMP003 Passive
YF4FE4000035 2145 050 DMP016 Active
YF4FE4000035 2145 050 DMP004 Active
References
IBM Redbook SG24-7994-00 “PowerHA SystemMirror for IBM i Cookbook”
IBM Redbook SG24-8197-00 “IBM i and IBM Storwize Family A Practical Guide to Usage Scenarios”